IntelliSense
®
Troubleshooting
FAQ
Application
Q: Can I use the IntelliSense
®
for single acting or reverse acting actuators?
A: Not at this time.
Q: Can I use IntelliSense
®
with SPCS valves?
A: Not at this time.
Q: Can I use a non-Bimba Actuator?
A: Bimba does not support IntelliSense
®
being installed on other manufacturers cylinders.
Q: What Bimba products is IntelliSense
®
compatible with?
A: IntelliSense
®
is compatible with Bimba Original Line, Single Rod, and Double Acting Cylinders. For compatibility
with other Bimba Cylinders please contact your Bimba representative.
Q: Can I use the IntelliSense
®
on a double end rod (DE option) actuator?
A: IntelliSense
®
is currently only congured for use with single rod end cylinders.
Q: How are the baseline numbers established?
A: The base line looks at the values over the specied number of cycles and reports back the observed averages.
Q: Is the use of cushions compatible with IntelliSense
®
?
A: Yes, the IntelliSense
®
is compatible with cushion applications.
Q: How does the IntelliSense
®
install on a cylinder?
A: The IntelliSense
®
Pressure and Temperature sensors are designed to be attached to pneumatic tubing using the
in line ttings provided in each IntelliSense
®
Kit. The tting is intended to be mounted 2-6 inches from the cylinder’s
ports. There should be no other devices between the cylinder and the sensor. The IntelliSense
®
sensors should not
be mounted directly to a cylinder.
Q: Can I use IntelliSense
®
with a quick exhaust valve?
A: Yes. IntelliSense
®
works with quick exhaust valves as long as the valve is not located between the cylinder and the
IntelliSense
®
sensor.
Q: Can I use IntelliSense
®
with ow controls?
A: Yes. IntelliSense
®
works with ow controls as long as the control is not located between the cylinder and the
IntelliSense
®
sensor.
Q: Can IntelliSense
®
be used on a lubricated system?
A: Yes, IntelliSense
®
may be installed in a lubricated system. Bimba’s installation recommendations should be fol-
lowed when installing the IntelliSense
®
system.
Q: What is the maximum cylinder frequency that can be detected?
A: IntelliSense
®
is designed to detect most cycle proles without additional tuning of the software. If IntelliSense
®
is
not detecting cycles after 5~10 cycles contact Bimba Customer Service for assistance with advanced tuning options.
Q: Can IntelliSense
®
be used with a multi-position cylinder?
A: No, IntelliSense
®
does not support use with multi-position cylinders.