IntelliSense
®
Manual
28
store these. These baseline values are then displayed in the Alert Detection section of the conguration
screen.
Figure 19: Baseline cycle count
Alert Detection
In the alert detection section, the user enters the limits that dene failure for a cylinder, or pressure and temperature
limits that will create an alert.
Cylinder Mode Alert Detection
Cylinder alerts indicate allowable ranges for cylinder performance and system parameters.
Extend time is the time required for the cylinder to extend outwards until the end of stroke or an obstacle causes
end of travel. Retract time is the time for the cylinder to retract. The direction of extend and retract is denoted by the
default location of the sensors with S1 on the cap side of the cylinder and S2 on the rod side.
Figure 20: Cylinder Mode sensor position
EXTEND
RETRACT
S1 S2