IntelliSense
®
Manual
46
The IntelliSense
®
SIM also stores the Real Time Clock Data and Identication labels, congured by the user, as ASCII
data in the following registers:
Table 5: ASCII MODBUS Registries
Using IntelliSense
®
I/O Connector
The IntelliSense
®
SIM unit’s I/O connector can be used to power the SIM or to utilize the two 3-wire NPN transis-
tor outputs. These outputs are congured to indicate the EOT (End Of Travel) sensed by the IntelliSense
®
system.
Cable part number CBL-IS-CF-0.5 is used to connect to the I/O connector. This cable is 0.5 meter in length, has
ying leads on one end, and a 4 pin connector on the other (Figure 55: Molex 50-57-9409 connector). The underside
of this connector has an arrow to indicate the location of pin 1 (Figure 56: Underside of Molex connector with Pin 1
Indicator).
User may also purchase the 4 pin connector through a 3
rd
party to wire for additional lengths as needed.
Figure 55: Molex 50-57-9409 connector
Figure 56: Underside of Molex connector with Pin 1 Indicator
Register Description Size
40501 RTC Seconds 2 bytes
40502 RTC minutes 2 bytes
40503 RTC hours (24hr) 2 bytes
40504 RTC hours (12hr) 2 bytes
40505 RTC AM/PM 2 bytes
40506 RTC day 2 bytes
40507 RTC month 2 bytes
40508 RTC year (last 2 digits) 2 bytes
40510 ID 1 string 60 bytes
40540 ID 2 string 40 bytes
40560 Part number 30 bytes