j. FAULT output
The DRV drives feature a digital FAULT output. This output closes to signal a
fault condition.
This output can be used to drive LEDs, relays and the inputs of other elec-
tronic devices like PLCs. The “+” (collector) and “-” (emitter) terminals of the
output transistor are available at the connector. This allows you to congure
the output for current sourcing or sinking. Diagrams of each type of connec-
tion follow.
Sinking Output
STR
5-24 VDC
Power Supply
+
Load
FAULT-
FAULT+
!
PLC
STR
5-24 VDC
Power Supply
+
FAULT-
FAULT+
IN
COM
Sourcing Output
Driving a Relay
STR
FAULT-
FAULT+
1N4935 suppression diode
5-24 VDC
Power Supply
+
relay
DRV
DRV
DRV
Do not connect the output to more than 30 VDC.
The current through the output terminal must not exceed 80 mA.