2014.01.23 rev4 4
1. Connecting to Valve
“With the air supply and power turned o”
1. Connect the SPCS-2 to the Bimba position feedback cylinder using cable SPCS-CBL-FBK.
2. If required, remove the top from the SPCS and congure internal jumper as shown in the illustration
below.
3. Connect the SPCS-2 to your power and command sources using cable SPCS-CBL-PWR-CMD.
4. Connect Pneumatic Lines.
a. Connect port 2 of the SPCS-2 to the back of the cylinder and port 4 to the front.
(3/8” O.D. tubing – 10’ or less length is recommended to prevent performance loss)
b. Inlet air should be dry (-40° F dew point) non-lubricated air, non-ammable & non-corrosive dry
gases (0.3 micron ne grade coalescing lter with 5 micron pre-lter) at 0-150psig.
c. Connect Inlet air to Port 1.
Power/Command & Feedback Connectors
Cable: SPCS-SBL-FBK
Cable: SPCS-CLB-PWR-CMD
5. Connect the valve to your computer using USB cable SPCS2-USB-CBL.
6. Must use a coalescing lter.