www.bimba.com Technical Assistance: 800-44-BIMBA 31
PFCN ELECTRICAL AND PNEUMATIC
CONNECTIONS
Note that for the PFCN,
power to the probe MUST
come from 24 VDC supplied
to the PCS control, and NOT
the 10 VDC that the PCS
produces from terminal A of
TB2.
If the Q (quick connect)
option was selected, the
connection to terminal A of
TB2 must be removed and
the lead reinserted into the
+24VDC terminal of TB1.
Also, insert a jumper
between TB1 ground and
TB2 terminal C (dotted blue
line).
Always insert a
jumper between
TB1 ground and
TB2 terminal C,
as shown by the
dotted blue line
to the right.